            Apollo High Pressure Non-Compliance PTCA Catheter

            Apollo High Pressure Non-Compliance PTCA Catheter
            • Brand Name : Apollo (BrosMed)
            • Category : Medical devices/Interventional Cardiology Devices
            • Place of Origin : China
            • Standard : ISO10555-1, ISO10555-4
            • Performance and Composition : NOM=12atm; RBP=22atm; average burst @30atm; 0.55% compliance
            • Scope : The balloon dilatation catheter is indicated for balloon dilatation of the stenotic portion of a coronary artery or bypass graft stenosis for the purpose of improving myocardial perfusion.
            • Description :
            • The Apollo Balloon Dilatation Catheter is designed to allow easy exchange of the catheter using a standard length guidewire. Balloon diameters range from 2.0mm to 5.0mm. The balloon material is made of a minimally compliant material with a rated burst pressure of 22 atmospheres for 2.0-4.0mm and 20 atmospheres for 4.5-5.0mm balloon respectively. The minimally compliant balloon material will allow high pressure dilatation while maintaining precise control of the balloon diameter and length. The proximal shaft of the catheter is composed of a female luer connector bonded to a PTFE coated stainless steel tube. The proximal shaft allows superior proximal pushability with a smooth transition to a distal shaft composed of an outer tube of nylon and a tri-extrusion inner tube with a balloon laser welded to both tubes at the distal tip. Two radiopaque tungsten plastic marker bands are positioned within the balloon shoulders. The inner tube accepts a standard 0.014 inch PTCA guidewire. The guidewire enters the catheter tip and advances coaxially out the distal Rx port, thereby allowing both coaxial guidance and rapid exchange of catheter with a single standard length guidewire. Two marked sections, 5mm in length located on the proximal shaft, indicate catheter position relative to the tip of either a brachial or femoral guiding catheter.
            Contact Info
            Contact: Mr. Benny Lee
            Tel: +86-769-2289 2018
            Email錛?/td> sales@brosmed.com
            Fax錛?/td> +86-769-2289 2016
            Web site錛?/td> http://www.brosmed.com
            Add錛?/td> 15th building,smes venture park,songshan lake hi-tech industrial development zone,dongguan 523808,guangdong,china
            P.C.錛?/td> 523808
            她在丈天面前被耍了三三视频
          1. <menuitem id="xc5cv"><strong id="xc5cv"><delect id="xc5cv"></delect></strong></menuitem>

                1. <track id="xc5cv"></track>
                  <bdo id="xc5cv"><address id="xc5cv"></address></bdo>